Product Overview
The Automatic Standby Generator is a standby power unit with an integrated automatic transfer switch for switching between utility and backup power during outages.
Technical Specifications
|
Category |
Parameter |
Typical Value |
|
Electrical |
Rated Power Output (Liquid Propane) |
26 kW |
|
Rated Power Output (Natural Gas) |
22.5 kW |
|
|
Rated Voltage |
120 / 240 V |
|
|
Rated Frequency |
60 Hz |
|
|
Rated Maximum Current (240V, LP) |
108.3 A |
|
|
Total Harmonic Distortion (THD) |
< 5.0% |
|
|
Power Factor (Single Phase) |
1.0 |
|
|
Engine & Fuel |
Engine Displacement / Cylinders |
999 cc / V-Twin |
|
Fuel Consumption (LP @ 50% Load) |
2.44 gal/hr (9.24 L/hr) |
|
|
Fuel Consumption (NG @ 50% Load) |
238 ft³/hr (6.74 m³/hr) |
|
|
Required Fuel Pressure |
3.5–7.0 inches W.C. |
|
|
Oil Capacity |
1.9 qt (1.8 L) |
|
|
Cooling System Type |
Air-Cooled |
|
|
Control & Automation |
ATS Current Rating |
200 A |
|
Response / Transfer Time |
10 seconds |
|
|
Exercise Cycle Duration |
5 minutes |
|
|
Connectivity |
Wi-Fi / Bluetooth / Cellular |
|
|
Physical & Environmental |
Sound Output (Normal Operation) |
65 dB(A) @ 7m |
|
Sound Output (Exercise Mode) |
57 dB(A) @ 7m |
|
|
Enclosure Material |
Aluminum with Powder Coat |
|
|
Operating Temperature Range |
-20°F to 104°F (-29°C to 40°C) |
|
|
Dimensions (L × W × H) |
48.0 × 25.0 × 29.0 in |
Engineering Features
Cold Start Kit
Battery warmer and oil heater reduce cold-start issues in low temperature conditions.
NEMA 3R Enclosure
Enclosure provides protection against rain, sleet, and external icing conditions.
SAE J1939 Protocol Integration
CAN-bus interface outputs engine operating data for monitoring systems.
Modbus Communication Architecture
RS-485 interface supports connection with standard building automation systems.
Applications
|
Application Sector |
Typical Use |
Key Benefits |
|
Residential Homes |
Backup for essential loads during outages |
Maintains basic power supply |
|
Healthcare Facilities |
Supports medical equipment |
Reduces interruption risk |
|
Data Centers |
Backup for servers and cooling systems |
Limits downtime |
|
Commercial Retail |
Supports POS and refrigeration |
Reduces operational loss |
|
Agricultural Farms |
Powers ventilation and controls |
Maintains system stability |
|
Telecommunications |
Backup for base stations |
Maintains signal continuity |
OEM/ODM & Customization Services
Voltage & Phase Reconfiguration
Adjusts alternator configuration for different grid standards.
Smart Controller Integration
Supports integration with external monitoring or building systems.
Fuel System Calibration
Adjusts fuel settings based on local gas properties.
RAL Color Matching
Enclosure color options based on project requirements.
Quality Control & Manufacturing Strength
100% Load-Bank Testing: Each unit is tested under step load conditions before shipment.
Salt-Spray Testing: Enclosure corrosion resistance is verified under accelerated conditions.
Vibration Analysis: Checks alignment between engine and alternator during operation.
CMM Inspection: Machined parts are measured for dimensional compliance.
Electrical Testing: Insulation and dielectric tests are performed on each unit.
Packaging & Logistics
Reinforced Wooden Pallets: ISPM 15 compliant pallets used for export handling.
Moisture Protection Wrapping: Plastic film used to reduce humidity exposure during shipping.
Shock Protection Pads: Foam inserts reduce vibration during transport.
Impact Indicators: External labels show whether impact occurred during handling.
Container Loading Design: Crate dimensions optimized for container utilization.
FAQ
Q: Can emission documents be provided for compliance use?
A: Yes, certification documents are available per production batch.
Q: What is the lead time for customized orders?
A: Typically 4–6 weeks depending on configuration.
Q: Does the system support remote updates?
A: Yes, updates can be applied via cloud access for supported controllers.
Q: What oil type is recommended?
A: SAE 5W-30 synthetic is commonly specified in documentation.
Q: Are replacement parts standard?
A: Many filters and plugs use industrial standard part numbers.
Q: How is over-crank protection handled?
A: The controller stops cranking after preset attempts and triggers an alarm.