Automatic Standby Generator

Automatic Standby Generator

The Automatic Standby Generator automatically restores backup power after utility failure, protecting essential residential and commercial loads without manual operation. It combines automatic transfer switching, outdoor installation capability and remote monitoring options in one standby power system.
Send Inquiry
Description
Technical Parameters

The Automatic Standby Generator automatically restores backup power after utility failure, protecting essential residential and commercial loads without manual operation. It combines automatic transfer switching, outdoor installation capability and remote monitoring options in one standby power system.

 

Technical Specifications

 

Category

Parameter

Specification

Electrical

Rated Power Output – LP

26 kW

Electrical

Rated Power Output – Natural Gas

22.5 kW

Electrical

Rated Voltage

120 / 240 V

Electrical

Rated Frequency

60 Hz

Electrical

Rated Maximum Current – LP, 240 V

108.3 A

Electrical

Total Harmonic Distortion

< 5.0%

Electrical

Power Factor

1.0, single phase

Engine

Displacement / Cylinders

999 cc / V-Twin

Engine

Cooling

Air-cooled

Fuel

LP Consumption @ 50% Load

2.44 gal/hr (9.24 L/hr)

Fuel

NG Consumption @ 50% Load

238 ft³/hr (6.74 m³/hr)

Fuel

Required Fuel Pressure

3.5–7.0 in. W.C.

Engine

Oil Capacity

1.9 qt (1.8 L)

Automatic Transfer

ATS Current Rating

200 A

Automatic Transfer

Response / Transfer Time

10 seconds

Exercise

Exercise Cycle Duration

5 minutes

Connectivity

Wireless Connectivity

Wi-Fi / Bluetooth / Cellular

Acoustic

Sound Output – Normal Operation

65 dB(A) @ 7 m

Acoustic

Sound Output – Exercise Mode

57 dB(A) @ 7 m

Enclosure

Material / Finish

Aluminum with powder coat

Environment

Operating Temperature

-29°C to 40°C

Dimensions

L × W × H

48.0 × 25.0 × 29.0 in.

 

Automatic Standby Power Operation

 

Utility Power → Power Failure Detection → Automatic Generator Start → Generator Ready → ATS Transfers Load → Utility Restored → Re-transfer & Shutdown

 

Automatic Utility Monitoring
The system monitors the utility supply and initiates the standby sequence when a power interruption is detected.

 

Automatic Generator Start
A utility failure triggers the generator start sequence without requiring manual startup.

 

Transfer Response
After the generator starts, the ATS transfers the connected standby load to generator power. The specified response / transfer time is 10 seconds.

 

Automatic Return to Utility
When utility power is restored, the ATS returns the load to the utility source and the generator shuts down before returning to standby mode.

 

Fuel Configuration & Load Selection

Liquid Propane Configuration

Provides 26 kW standby output at 120/240 V. Suitable for locations requiring onsite fuel storage or without natural gas access.

Natural Gas Configuration

Provides 22.5 kW standby output at 120/240 V. Suitable for buildings with existing natural gas connections and continuous fuel supply.

Fuel Selection

Select LP or natural gas based on site fuel availability, installation conditions and required standby capacity.

Standby Load Selection

Size the connected loads according to running power demand and motor starting requirements for essential equipment.

 

Control, Monitoring & Communication

 

Exercise & Standby Control
The control system manages scheduled exercise cycles and automatic standby operation to keep the generator ready for outages.

 

Remote Monitoring
Wi-Fi, Bluetooth and cellular connectivity allow remote status checking and generator monitoring.

 

System Integration
SAE J1939, CAN-bus and RS-485 Modbus communication support connection with compatible building management and monitoring systems.

 

Outdoor Installation & Cold-Weather Configuration

01/

Outdoor Installation
The NEMA 3R enclosure protects the generator from rain, sleet and external icing conditions for outdoor placement.

02/

Environmental Protection
The aluminum powder-coated enclosure supports outdoor operation within the specified temperature range of -29°C to 40°C.

03/

Cold-Weather Operation
Optional battery warmer and oil heater kits support starting performance in low-temperature environments.

04/

Installation Considerations
Installation should consider ventilation, service clearance and local requirements for safe generator operation.

 

Applications

 

Residential Backup Power
Supports essential household loads including lighting, refrigeration, HVAC systems and security equipment during utility outages.

 

Small Commercial Buildings
Suitable for offices, retail spaces and small facilities requiring automatic standby electricity.

 

Remote Locations
Provides backup power for areas with unstable grid supply or limited access to utility services.

 

Configuration & OEM Options

 

Voltage & System Configuration
Alternator and electrical configurations can be adjusted according to project voltage and application requirements.

 

Fuel System Adjustment
Natural gas fuel settings can be configured based on local gas conditions.

 

Enclosure Customization
RAL color matching is available for project-specific appearance requirements.

 

Factory Testing & Quality Control

Load-Bank Testing

Each unit undergoes 100% load-bank testing under step-load conditions before shipment.

Electrical Testing

Insulation and dielectric tests are performed on each unit before shipment.

Enclosure & Vibration Testing

Salt-spray testing checks enclosure corrosion resistance, while vibration analysis checks engine-to-alternator alignment during operation.

Dimensional Inspection

CMM inspection is used to measure machined parts for dimensional compliance.

 

Packaging & Export Logistics

 

Wooden Pallets
Export shipments use ISPM 15-compliant reinforced wooden pallets for international handling.

 

Moisture Protection
Plastic film is used to reduce humidity exposure during transportation and storage.

 

Shock Protection
Foam protection pads are used to reduce vibration and impact during handling.

 

Container Loading
Crate dimensions are planned for container utilization, helping optimize loading space for export shipments.

 

FAQ

 

Q: What is the lead time for customized orders?

A: Customized orders typically require 4–6 weeks, depending on the selected configuration.

Q: Can emission documents be provided?

A: Emission certification documents are available per production batch according to the current product documentation.

Q: Are replacement parts based on standard specifications?

A: Many filters and plugs use industrial-standard part numbers, which can simplify replacement-part sourcing.

Q: Does the controller support remote updates?

A: Cloud-based updates are available for supported controllers.

Q: What oil specification is recommended?

A: The current product documentation commonly specifies SAE 5W-30 synthetic oil; the applicable specification should be confirmed for the supplied configuration.