Single Phase Diesel Generator

Single Phase Diesel Generator

The single-phase diesel generator is a compact, heavy-duty prime and backup power unit that converts diesel fuel into stable 230 V AC. It powers single-phase tools, water pumps, lighting towers, emergency systems, and telecommunications equipment in off-grid or power-sensitive environments.
Send Inquiry
Description
Technical Parameters

The single-phase diesel generator is a compact, heavy-duty prime and backup power unit that converts diesel fuel into stable 230 V AC. It powers single-phase tools, water pumps, lighting towers, emergency systems, and telecommunications equipment in off-grid or power-sensitive environments.

p2025101315060488384

 

Technical Specifications

 

Category

Item

Specification (Unit)

Electrical

Prime Power

10 kW

Standby Power

11 kW

Rated Voltage

230 V

Rated Frequency

50 Hz

Rated Current

43.5 A

Power Factor

1.0

THD

< 5 %

Engine

Model

1102F

Type

Single-cylinder, 4-stroke, air-cooled

Rated Speed

3000 rpm

Displacement

0.718 L

Fuel

Fuel Consumption (100% load)

2.8 L/h

Fuel Tank Capacity

15 L

Runtime (75% load)

7.1 h

Oil Capacity

1.65 L

Alternator

Type

Brushless, AVR controlled

Insulation Class

Class H

Protection

Protection Class

IP23

Structure

Noise Level (@7m)

68 dB(A)

Dimensions

1100 × 660 × 770 mm

Net Weight

210 kg

Control

Control System

Smart LCD controller

 

Applications

 

Application Field

Typical Use

Key Benefits

Residential Backup

Emergency backup power during grid outages

Provides limited household backup power during grid outage

Small Business

Runs shops, offices, and POS systems

Reduces downtime during short grid interruptions

Mobile Food Service

Supports cooking and refrigeration equipment

Supports off-grid operation needs

Construction Site

Operates tools and temporary lighting

Supports temporary on-site power for tools and lighting

Agriculture

Drives pumps, fans, and fencing systems

Supports operational reliability in field use

Telecom Stations

Supports backup power for communication equipment

Provides backup power for communication equipment during outages

Outdoor Events

Powers lighting and sound systems

Provides temporary power for event use

 

Engine & Alternator Configuration

 

Engine Model: Heavy-duty single-cylinder 4-stroke air-cooled diesel engine built for continuous prime power, eliminating radiator leaks and coolant maintenance costs.

 

Brushless Alternator: Features Class H 180°C thermal insulation to sustain continuous high-temperature operation without carbon brush replacement downtime or internal electrical sparking.

 

AVR Voltage Regulation: Integrated Automatic Voltage Regulator stabilizes terminal output during high-amp inductive motor starts, protecting system electronics from voltage sag.

 

Direct-Coupled Powertrain: Rigid engine-to-alternator coupling eliminates drive-belt slippage, power-transfer losses, and periodic belt replacement.

 

Electrical Output & Load Performance

01/

Low Waveform Distortion (THD <5%): Keeps Total Harmonic Distortion under 5% at 100% rated load, protecting sensitive microprocessor controls from thermal overload.

02/

Voltage Stability (±1.5%): The AVR maintains terminal voltage accuracy within ±1.5% during instantaneous step-load transitions from 0% to 100%.

03/

Frequency Regulation (±1 Hz): The mechanical governor maintains steady-state frequency within ±1 Hz under stable operating loads.

04/

Inductive Load Surge Absorption: Engineered to absorb high starting current spikes from single-phase induction motors without triggering low-voltage cutoffs.

05/

230V / 50Hz Grid Interfacing: Connects directly into standard 230V/50Hz single-phase distribution panels without requiring external step-down transformers.

 

Fuel Consumption & Runtime

 

p20251013150608d68e8

• Consumes 2.8 L/h of diesel fuel under continuous 100% prime electrical load.


• Delivers 7.1 hours of continuous runtime at 75% load on a 15L fuel tank, covering complete overnight shifts without refueling.


• Direct-injection combustion maximizes energy yield per liter of fuel, reducing operational power costs per kilowatt-hour.


• Standardized 1.65 L crankcase accommodates regular multi-grade 15W-40 diesel engine oil.

 

OEM & Customization Services

 

• Custom silkscreen logo application, brand nameplates, and customized metal badge plates.


• Custom powder-coated canopy paint finishes matched to distributor or corporate RAL color codes.


• Private-labeled user manuals, electrical schematics, and maintenance guides in local languages.


• Custom control panel overlay design and multilingual LCD controller software options.

p2025101315061141e0b

 

Manufacturing Capabilities

 

p2025101315061592b45

Owned Production Facility: Milestone (Hebei Xiong'an) Technology Co., Ltd. operates complete in-house engine and genset assembly lines.

 

Precision CNC Machining: The plant utilizes CNC machining centers and automated milling for high-tolerance engine components and frame structures.

 

Dedicated Assembly Lines: Specialized manufacturing tracks for open-frame, silent canopy, trailer-mounted, and marine generator sets.

 

Scalable Output: Infrastructure built to supply high-volume distributor stock orders and customized commercial project tenders.

 

FAQ

 

Q: Does it come with a sound-attenuated enclosure?

A: Yes, the standard canopy is rated at 70 dBA at 7 meters under full load; the compact air-cooled design runs slightly louder than larger water-cooled silent models but remains within typical limits for job-site and residential backup use.

Q: What is the maximum ambient temperature this generator can handle under continuous 100% load without overheating?

A: The air-cooled engine is rated for continuous full-load operation up to 40°C ambient temperature; sustained operation above this threshold may require load reduction to prevent thermal shutdown.

Q: What is the rated power output of this single-phase generator?

A: This model is rated at 6 kW prime power (6.6 kW standby) at 230V single-phase, suited for tools, water pumps, and lighting towers within that load range.

Q: Can this generator run unattended overnight without risk of overheating or running dry on oil?

A: Yes, the 1.65 L crankcase and 15 L fuel tank support a full unattended overnight shift at 75% load for up to 7.1 hours. Automatic low-oil-pressure shutdown protects the engine if oil levels fall below the safe operating range.

Q: What is the warranty period for this generator?

A: The standard factory warranty covers the engine and alternator for 12 months or 1,000 operating hours, whichever comes first.

Q: What is the minimum order quantity and standard production lead time?

A: MOQ is 5 units for standard configurations, with production lead time of 15-20 calendar days from order confirmation.