Product Overview
Single Phase Diesel Generator converts engine mechanical power into 230V AC output for single-phase electrical loads. The unit is designed for standby and light-duty prime use under rated operating conditions.

Technical Specifications
|
Category |
Item |
Specification (Unit) |
|
Electrical |
Prime Power |
10 kW |
|
Standby Power |
11 kW |
|
|
Rated Voltage |
230 V |
|
|
Rated Frequency |
50 Hz |
|
|
Rated Current |
43.5 A |
|
|
Power Factor |
1.0 |
|
|
THD |
< 5 % |
|
|
Engine |
Model |
1102F |
|
Type |
Single-cylinder, 4-stroke, air-cooled |
|
|
Rated Speed |
3000 rpm |
|
|
Displacement |
0.718 L |
|
|
Fuel |
Fuel Consumption (100% load) |
2.8 L/h |
|
Fuel Tank Capacity |
15 L |
|
|
Runtime (75% load) |
7.1 h |
|
|
Oil Capacity |
1.65 L |
|
|
Alternator |
Type |
Brushless, AVR controlled |
|
Insulation Class |
Class H |
|
|
Protection |
Protection Class |
IP23 |
|
Structure |
Noise Level (@7m) |
68 dB(A) |
|
Dimensions |
1100 × 660 × 770 mm |
|
|
Net Weight |
210 kg |
|
|
Control |
Control System |
Smart LCD controller |
Applications
|
Application Field |
Typical Use |
Key Benefits |
|
Residential Backup |
Emergency backup power during grid outages |
Provides limited household backup power during grid outage |
|
Small Business |
Runs shops, offices, and POS systems |
Reduces downtime during short grid interruptions |
|
Mobile Food Service |
Supports cooking and refrigeration equipment |
Supports off-grid operation needs |
|
Construction Site |
Operates tools and temporary lighting |
Supports temporary on-site power for tools and lighting |
|
Agriculture |
Drives pumps, fans, and fencing systems |
Supports operational reliability in field use |
|
Telecom Stations |
Supports backup power for communication equipment |
Provides backup power for communication equipment during outages |
|
Outdoor Events |
Powers lighting and sound systems |
Provides temporary power for event use |
OEM Capability & Customization Options

Canopy color matching via powder coating based on RAL codes.
Private labeling is available with laser nameplates and silk-screen logos based on customer artwork.
Control interfaces can be configured for multi-language operation depending on destination market requirements.
Skid and frame structure can be adjusted with lifting points, forklift slots, and vibration isolation mounts.
Circuit breaker brands and protection components can be integrated according to project specification.
Quality Control & Certifications
Quality Control Process
• Load testing is performed at 25%, 50%, 75%, and 100% load levels for output verification before shipment.
• Transient response is checked under 50% step load to confirm voltage recovery time within ≤ 2 seconds.
• Noise level is measured at 7 meters under rated load conditions with enclosure installed.
• Fuel system pressure testing is conducted at 1.5× working pressure to check sealing integrity.
• Protection functions are validated through simulated fault conditions including low oil pressure and overspeed shutdown.
• Each unit completes a minimum 2-hour continuous loaded run before shipment to confirm thermal and voltage stability.
Compliance & Certificates
|
Certification |
Verification Effect |
|
CE Marking |
Confirms compliance with EU safety and environmental requirements |
|
ISO 9001:2015 |
Verifies factory quality management system compliance |
|
ISO 14001:2015 |
Confirms environmental management system implementation |
|
EPA Tier 4 / Stage V |
Confirms engine emissions compliance with applicable regulations |
|
UL 2200 Compliance |
Validates safety requirements for stationary generator sets |
|
CSA Certification |
Confirms compliance with Canadian electrical safety standards |
|
IP23 Protection Rating |
Confirms enclosure protection against dust and water spray |
Factory Strengths & Manufacturing Process
Key structural components are produced using in-house CNC machining centers to control dimensional consistency.
Steel enclosures are processed through automated powder coating lines for corrosion resistance under standard environmental exposure.
Monthly production output is approximately 2,500 units, depending on configuration and component availability.
Standard lead time is 25–30 days after deposit confirmation for regular orders.
Component sourcing is managed through a controlled supplier system to maintain delivery consistency across production batches.

Packaging, Loading & After-Sales Support

Each unit is protected with multi-layer wrapping including stretch film and foam corner protection to reduce handling damage.
Packaging uses ISPM-15 certified fumigated wooden crates suitable for international sea freight transport.
A complete technical documentation set, including wiring diagrams and operation manuals, is included in each shipment.
Standard warranty coverage is 12 months or 1,000 operating hours, whichever comes first, covering manufacturing defects.
Core spare parts are stocked continuously to support maintenance over the product lifecycle.
FAQ
Q: Do you provide custom color matching for the generator canopy?
A: Color matching based on RAL codes is available during production.
Q: Can mixed models be loaded in one container?
A: Mixed loading is supported depending on configuration compatibility.
Q: Can our logo be applied to the control panel?
A: Branding can be applied using silk-screen or overlay labeling based on artwork.
Q: How is corrosion prevented during ocean shipping?
A: Units are protected using vapor corrosion inhibitors and sealed packaging layers.
Q: Can we specify circuit breaker brands?
A: Component brand selection is available upon technical confirmation.
Q: What is the MOQ for custom outlets?
A: Minimum order quantity is 10 units for non-standard outlet configurations.
Q: Is a tool kit included?
A: A basic maintenance toolkit is included in each unit shipment.
Q: Can extra filters be shipped with the order?
A: Additional consumables can be included upon request during order placement.