Diesel Backup Generator Set

Diesel Backup Generator Set

The 400 kVA Diesel Backup Generator Set provides 400 kVA / 320 kW standby power and 365 kVA / 292 kW prime power for utility-outage and extended-duty applications. It uses a Cummins 6TAA8.9-G3 diesel engine, DSE 7320 MKII controller and automatic transfer system for backup power operation.
Send Inquiry
Description
Technical Parameters

The 400 kVA Diesel Backup Generator Set provides 400 kVA / 320 kW standby power and 365 kVA / 292 kW prime power for utility-outage and extended-duty applications. It uses a Cummins 6TAA8.9-G3 diesel engine, DSE 7320 MKII controller and automatic transfer system for backup power operation.

 

Technical Specifications

 

Item

Specification

Engine Model

Cummins 6TAA8.9-G3

Engine Speed

1500 rpm at 50 Hz / 1800 rpm at 60 Hz

Cylinders

6 in-line

Displacement

8.9 L

Aspiration

Turbocharged aftercooled

Standby Power

400 kVA / 320 kW

Prime Power

365 kVA / 292 kW

Voltage

400 V / 230 V, adjustable 380–415 V

Frequency

50 / 60 Hz

Phase

3-phase, 4-wire

Voltage Regulation

≤±1.0%

Frequency Regulation

≤±0.5%

Controller

DSE 7320 MKII

ATS Transfer Time

≤10 s

Fuel Consumption

197 g/kWh, approx. 85.2 L/h at 100% load

Fuel Tank

750 L

Enclosure

Soundproof canopy

Noise Level

≤75 dB(A) at 7 m

Dimensions

4200 × 1450 × 2150 mm

Weight

3850 / 3950 kg

 

Backup Power & Load Matching

 

Standby Rating
The 400 kVA / 320 kW standby rating is intended for utility-outage operation. Generator capacity should be matched to the loads requiring backup.

 

Prime Rating
The 365 kVA / 292 kW prime rating applies when the generator is required to operate for extended periods. Select the applicable rating according to the operating duty.

 

Load Assessment
Check running load, motor-starting demand and load variation before sizing. Pumps, fans and compressors should be included where applicable.

 

Electrical Matching
Confirm generator voltage, frequency and phase against the site distribution system before order placement.

 

Automatic Backup Power System

 

Utility Failure → Failure Detection → Generator Start → Output Stabilization → ATS Transfer → Backup Power → Utility Recovery → Load Re-transfer → Generator Shutdown 

Utility Failure Detection

The ATS detects utility power failure and initiates the generator start sequence.

Generator Start & Stabilization

The generator starts automatically and establishes the required voltage and frequency before load transfer.

Automatic Load Transfer

The ATS transfers the backup load from utility power to the generator, with a specified transfer time of ≤10 seconds.

Utility Recovery

When utility power returns and stabilizes, the ATS transfers the load back to the mains and the generator completes its shutdown sequence.

 

Engine, Alternator & Control System

 

Diesel Engine
The Cummins 6TAA8.9-G3 uses six in-line cylinders, 8.9 L displacement and turbocharged aftercooling, with 1500 rpm / 1800 rpm operation for 50 / 60 Hz.

 

Alternator
The generator provides 400 kVA / 320 kW standby and 365 kVA / 292 kW prime output, with voltage regulation ≤±1.0% and frequency regulation ≤±0.5%.

 

Controller
A DSE 7320 MKII controller provides the generator control and monitoring interface.

 

Engine Protection
Protection functions include low oil pressure, high temperature and overspeed shutdown.
 

Fuel Capacity & Runtime Planning

01/

Fuel Tank
The standard configuration uses a 750 L fuel tank for backup operation.

02/

Fuel Consumption
Fuel consumption is approximately 85.2 L/h at 100% load, based on the specified 197 g/kWh rate. Actual consumption varies with load.

03/

Runtime Reference
At the listed full-load consumption, 750 L provides a theoretical runtime of approximately 8.8 hours. Actual runtime depends on operating load.

04/

Extended Runtime
8-, 12- and 24-hour fuel tank configurations are available for projects requiring longer operation between refueling.

 

Project Configuration & Installation

 

Soundproof Configuration
The generator is supplied with a soundproof canopy, with noise specified at ≤75 dB(A) at 7 m. Overall dimensions are 4200 × 1450 × 2150 mm.

 

Installation Space
Allow sufficient space around the generator for ventilation, exhaust discharge, fuel handling and routine maintenance.

 

Fuel Configuration
The standard 750 L tank can be replaced with 8-, 12- or 24-hour extended-run configurations according to the required backup duration.

 

Export Packaging
Export units can be protected with VCI film, secured to heavy-duty wooden skids and packed in ISPM 15-compliant wooden crates. Container lashing is used for transport securing.

 

Testing & Documentation

Load Bank Testing

Each assembled unit undergoes a 0–110% load test to check generator output performance and overspeed protection before shipment.

Fuel Tank Testing

Fuel tanks undergo 100% hydrostatic testing to check weld integrity before delivery.

Insulation Testing

Insulation resistance is tested on the electrical system before shipment.

Vibration Analysis

ISO 8528 vibration analysis is performed at full operating load, with factory test records available for the completed generator set.

 

20260115133306d72e7

 

FAQ

 

Q: What is the standard warranty period?

A: The standard warranty is 12 months or 1,000 operating hours, whichever comes first.

Q: Are spare parts available after purchase?

A: Yes. Routine maintenance parts and replacement components can be supplied according to the selected generator configuration.

Q: What is the typical production lead time?

A: Standard production typically requires 15–25 business days after order confirmation, depending on configuration and order quantity.

Q: What information is required for quotation?

A: The required power, voltage, frequency, phase, quantity, operating duty and installation requirements should be confirmed before quotation.

Q: Can factory inspection be arranged before shipment?

A: Yes. Factory testing records can be provided, and remote witnessing of load-bank testing can be arranged upon request.